Fire Alarm

NITTAN
WORLD CLASS FIRE ALARM

nittan fire alarm

[metaslider id=144]

Hand in hand with fire protection governance, Nittan places continual efforts every day in technological developments and service enhancements towards the protection of our customers’ lives and property from fire.

As a company dedicated to society, Nittan has aimed to be a technology company as dictated by its Code. Since establishment in 1954, we have maintained an overarching vision that encompasses markets worldwide, and have maintained our “people first” belief and philosophy of harmony.

Technology and quality remain a top priority in earning the trust of our customers. Members of the company take the Code to heart in their service of disaster prevention enterprises: with the integrity of a pure heart, with the utmost courtesy, and with the passion and courage to energize oneself.

 

Nittan Spera NFU 7000

NITTAN SPERA NFU 7000
system configuration

nittan spera nfu 7000

FEATURES NITTAN SPERA NFU 700 :

  • One driver card capable of 2 loops is equipped as standard
  • NITTAN SPERA NFU-7000 has 3 capability of driver card storage (max 6 loops), NFU-7000-L has 7 capability (max 14 loops)
  • One loop supports 254 addresses which can be wired in Class A (Style 6 or 7) or Class B (Style 4)
  • Use of shielded cable is not required for SLC loops
  • Modular design
  • Four Class A/B (Style Z/Y) Notification Appliance Circuits rated at 1.7 Amps each
  • One Auxiliary power supply, rated 1.7 Amps at 24VDC in addition to one resettable 4-wire power supply
  • Large 16 line x 40 character Back-lit LCD Display with user friendly menu
  • Correlatable Switch Inputs which allow for multifunctional outputs
  • Four Status Queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Monitor
  • Auxiliary relay contacts for Common Alarm, Common Supervisory and Common Trouble
  • RS-232 port for remote system printer
  • Two Event History Logs comprised of a 1000 event alarm history log for alarm related events and a 5000 event log for all events
  • Supports three configuration files (current, previous and next configuration) with “hot swap” support
  • Supports Conventional Hardwire Adder Modules
  • Built-in One Man Walk Test operation
  • Provides drift compensation for Photoelectric Smoke Detectors
  • Capability to adjust Intelligent Smoke Detector sensitivity levels
  • Real time 3D graphical monitoring and control using Nittan’s NFU-Graphic-monitor
  • BACnet support
  • Supports Boolean logic functions
  • Built-in Ethernet port
  • UL listed for Smoke Control
  • Manual Control Function
  • Input Simulation Function
  • Multiple group bypass function with built-in false alarm prevention technology
    • Network Node Bypass
    • Node Outputs Bypass
    • Input Zone Bypass
    • Relay Disconnect
    • Device/Circuit Bypass

Network Features

  • Up to 63 panels
  • Peer-to-peer network communications
  • Mutual surveillance / 2 way control available
  • Class A (Style 6 or 7) or Class B (Style 4) wiring configuration
  • Arcnet Network Communications protocol
  • Supports copper and/or fiber optic network cable

Nittan SPERA fire alarm

NITTAN SPERA
Analog Addressable Fire Alarm System

nittan SPERA fire alarm

Nittan SPERA fire alarm NFU-7000 Series Network Fire Alarm Control Panels offer modular components for a network system providing a wide variety of applications. Designed for peer-to-peer network communications, the NFU-7000 allows for a maximum of 63 nodes, while providing reliability, flexibility and expandability.
nittan spera fire alarmThe Nittan SPERA NFU-7000 EV protocol is based on the platform which acquired reliabilities in European and Marin markets. Each base panel consists of one driver circuit board which is capable of driving 2 loops. A Nittan EV protocol supports 254 addresses. Owing to the contribution of expandability, addressable detectors and modules are available to be installed without constraint of address number allocation.
In addition the base panel includes Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each and a large 16 x 40 back-lit alphanumeric LCD display.
NFU-7000 panel can see other panels’ condition of the same network. Each panel can be configured using standard NFU-7000 components.
The network interface module allows the panels to communicate on a peer-to-peer network via an industry standard ARCnet protocol. The network capabilities allow site specific customization and the ability to meet local and national requirements.